<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-21 21-17-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.10 MHz 4/5, 41 dBuV CauseCom
Pilot RDS Phase Difference
8.0 kHz 4.0 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
17 kHz 28 kHz 1611 0,8070
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
3,3 dBr 4,02 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"CauseCom" FE46 9 (Varied) 0 0 1 1 --:--
RT
" "
AF EON
-
FM Scope Station: 93.10 MHz, signal: 4/5 (41 dBuV) Max at: 28 kHz MIN: 17 kHz % above 75 kHz: 0,8070 Acquired: 2025/01/21 21:16:52 Total samples: 1611 Equivalent time: 0:01:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40
FM Scope MAX: 4,7 dBr MIN: 3,3 dBr AVE: 4,02 dBr % above 10,0 dBr: 0,0 Last value: 4,6 dBr (2025/01/21 21:16:52) Station: 93.10 MHz, signal: 4/5 (41 dBuV) 21:10 21:11 21:12 21:13 21:14 21:15 21:16 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality